<LOGO>
FM Transmitter Measurement Report
Created: 2026-11-04 21-26-00
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 44 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 58 kHz 2818 0,0355
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,8 dBr 5,19 dBr 5,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 58 kHz MIN: 12 kHz % above 76 kHz: 0,0355 Acquired: 2026.11.04 21.24.56 Total samples: 2818 Equivalent time: 0:02:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100
FM Scope MAX: 5,8 dBr MIN: 3,8 dBr AVE: 5,19 dBr % above 12,2 dBr: 0,0 Last value: 4,3 dBr (2026.11.04 21.24.56) 21.12 21.14 21.16 21.18 21.20 21.22 21.24 0 2 4 6 Pm [dBr]